微电网孤岛检测方法的比较与分析

2015-05-27 16:11来源:能源与节能作者:安晓静关键词:微电网孤岛检测电能质量收藏点赞

投稿

我要投稿

摘 要: 孤岛检测技术是微电网在特定情况下由并网运行模式向孤岛运行模式转换的必不可少的前提条件。总结了目前孤岛检测的各种方法,详细分析了各种常用的主动检测法和被动检测法在电能质量和检测盲区等方面的优缺点。

关键词: 孤岛检测;主动检测;被动检测

中图分类号: TP274+.5 文献标识码:A 文章编号

Comparison and Analysis of the Micro-grid Islanding Detection Methods

AN Xiao-jing, CUI Yu

(Zhecheng Power Supply Co., Ltd. of Henan Province, Shangqiu 476200, Henan, China)

Abstract: Islanding detection technology is an essential prerequisite for micro-grid to transform from grid connected operation mode to islanding operation mode under certain circumstances. Summarizes the current various kinds of islanding detection methods, analyzes the advantages and disadvantages of various commonly used active and passive detection methods in the aspects of the quality of electric energy and non detection zone, etc. in detail.

Keywords: islanding detection; active detection; passive detection

0 引言

在大电网中接入微电网后,两者可以互相支持,提高电网的可靠性。对大电网来说,若微电网规模达到一定的程度,可以提高大电网运行的经济性。当大电网的稳定运行受到扰动的威胁时,微电网中分布式电源可以为重要负荷提供电能和电压、频率支撑,从而提高供电可靠性。如果电网的电能质量不能满足用户要求或者电网发生故障,微电网由并网运行模式转入孤岛运行模式,保证了区域供电的可靠性和灵活性[1,2]。然而,在两种运行模式下,微电网中的分布式电源需要采用不同的控制策略。因此,必须要保证微电网由并网运行模式向孤岛运行模式的平稳过渡。

本文以孤岛检测技术为重点,分析总结了常用的主动检测法和被动检测法在电能质量和检测盲区等方面的优缺点。

1 孤岛检测的基本方法

孤岛检测技术起源于分布式电源的应用,目前孤岛检测方法主要有三类:主动检测法、被动检测法和开关状态监测法[3-5]。开关状态监测法是一种基于高速实时通信技术的方法,虽然其运行效果良好,但是由于需要大量安装通信设备,导致造价较高,操作复杂,因此通常情况下不考虑这种方法。下面主要介绍依靠本地检测的主动检测法和被动检测法。

1.1 主动检测法

主动检测法是指通过逆变器人为的向系统中加入1个有源扰动信号。并网运行时,由于受到大电网的制约,扰动信号作用非常小,不会对测量产生影响;当孤岛产生时,逆变器输出的扰动会迅速累积,超出允许范围时触发孤岛检测装置。该方法优点在于可以减小检测盲区,但引入的有源扰动会对微电网孤岛运行产生负面影响。